The UC-282 is designed to expand a number of wireless zones of UC-281 or UC-282 wireless interface. It provides additional 8 zones interface linking JA-60 wireless detectors or RC-xx remote controls with hard-wired security control panels.
The UC-282 cannot be used independently, as it is not equipped with receiver or transmitter module.
|
| Up to 4 UC-282 expander modules can be used to increase the number of zones of UC-281 or UC-282. |
|
| Power |
12 V DC (10.5 V - 16.0 V) |
| Power consumption |
typ. 50 mA (all relays off)
max. 150 mA |
| Zone outputs Z1-Z8 |
8 relays 50 mA / 50 V
with COM1 common terminal |
| Tamper, fault, battery outputs |
3 relays 50 mA / 50 V
with COM2 common terminal |
| Working environment |
indoor use (class II, EN 50131-1) |
| Operating temperatures |
-10 °C to +70 °C |
| Operating humidity |
max. 90 % |
| Dimensions |
188 x 135 x 40 mm |
| Weight |
800 g |
|
|